Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published by Scroll Versions from space ZAMCD and version 3.20

...

Configuration

Range

Measurement

Default

Description

I2C settingsConfigures I2C on the TSM
Address0 to 1278 to 119 (0x8 to 0x77)7-bit value80 (0x50)The I2C I2C address for the TSM. NOTE: Addresses 0-7 and 120-127 are I2C reserved addresses and should not be used.
System EnabledConfigures the startup state of the TSM
System EnabledTrue/FalseBooleanTrueEnables or disables the TSM
Operation ModeConfigures the default operation mode
detectionTrue/FalseBooleanTrueOperation mode ASN.1 over either I2C or USB Raw HID
detectionHIDTrue/FalseBooleanTrueOperation mode USB HID
Range SettingsSets the scanning range dynamically
Scanning Range

Mechanical Data

10-1·mm

Mechanical Data (col. B * 10)

The area (width and height) the Touch Sensor Module (TSM) will scan for an object with lasers and photodiodes (PD). 

This value also sets the limit for High Y (Max Y) below.

Frequency SettingsChanges the Touch Sensor Modules update frequency
Idle FrequencyFrequencyHz33Scanning frequency when the Touch Sensor Module has not registered any touch object.
Finger Frequency
Frequency
Hz100Scanning frequency when the Touch Sensor Module has registered and tracking a touch object.
Touch Active Area AdjustmentsContains settings for modifying the active touch area and the reported touch coordinates

Low Bound X (Min X)

Mechanical Data

10-1·mm

36

Start position of the Touch Active Area (TAA) in X-direction. Low X, High X, Low Y & High Y make up the TAA. 

Low Bound Y (Min Y)

Mechanical Data

10-1·mm

0

Start position of the Touch Active Area (TAA) in Y-direction. Low X, High X, Low Y & High Y make up the TAA. 

High Bound X (Max X)

Mechanical Data

10-1·mm

Mechanical Data (col. A * 10) + 36

End position of the Touch Active Area (TAA) in X-direction. Low X, High X, Low Y & High Y make up the TAA. 

High Bound Y (Max Y)

Mechanical Data

10-1·mm

Mechanical Data (col. B * 10)

End position of the Touch Active Area (TAA) in Y-direction. Low X, High X, Low Y & High Y make up the TAA. 

Reverse X

True/False

Boolean

False

Reverses the X-coordinates of reported touches. Note, that the origin of the vast majority of the displays is in the top left corner.

Reverse Y

True/False

Boolean

False

Reverses the Y-coordinates of reported touches. Note, that the origin of the vast majority of the displays is in the top left corner.

Flip XY

True/False

Boolean

False

Swaps the Y- with the X-coordinates of the reported touches.

Offset X

Mechanical Data

10-1·mm

0

Offsets the projected TAA in X-direction, on the display.

Offset Y

Mechanical Data

10-1·mm

0

Offsets the projected TAA in Y-direction, on the display.

HID Display SizeThe size of the display reported by the Touch Sensor Module to the host. Only usable when connecting with USB HID

Hid Display Size X

Mechanical Data

10-1·mm

Mechanical Data (col. A * 10)

Width of the physical display. It is very important to set this parameter correct since the TSM will report touch coordinated in percentage of the physical display length/height.

Hid Display Size Y

Mechanical Data

10-1·mm

Mechanical Data (col. B * 10)

Height of the physical display. It is very important to set this parameter correct since the TSM will report touch coordinated in percentage of the physical display length/height.

SnappingConfigure the snapping area around the edges of the Touch Active Area (TAA)
EnabledTrue/FalseBooleanFalseEnables or disables the snapping filter.
Left InnerMechanical Data10-1 mm0Distance from edge to the inner snapping edge, left side of TAA.
Left OuterMechanical Data10-1 mm0Distance from edge to the outer snapping edge, left side of TAA.
Right InnerMechanical Data10-1 mm0Distance from edge to the inner snapping edge, right side of TAA.
Right OuterMechanical Data10-1 mm0Distance from edge to the outer snapping edge, right side of TAA.
Top InnerMechanical Data10-1 mm0Distance from edge to the inner snapping edge, top side of TAA.
Top OuterMechanical Data10-1 mm0Distance from edge to the outer snapping edge, top side of TAA.
Bottom InnerMechanical Data10-1 mm0Distance from edge to the inner snapping edge, bottom side of TAA.
Bottom OuterMechanical Data10-1 mm0Distance from edge to the outer snapping edge, bottom side of TAA.
Click On TouchConfigures the Touch Sensor Module to send an Up (touch event) after Down within a defined threshold to create an instant touch experience
Enabled

True/False

Boolean

FalseEnables and disables the Click On Touch Feature
Time To Up
ms100Time from the Down event until the Up event is sent.
Distance
10-1·mm100Distance from the initial location that a touch must stay within for Click On Touch to be enabled for a touch
Floating Protection SettingsWait for the object to stabilize on the Y-axis, in order to identify the position of the object in a reliable way. This parameter should not be set at the same time as Double-Click Prevention is turned on.
Enabled

True/False

Boolean

TrueFloating protection enabled.
Floating Protection Time
ms40040Time to wait before reporting touch registration.
Double-Click Prevention Settings

Configuration of the filter prevention area and timeout. This parameter should not be set at the same time as Floating Protection is turned on.
EnabledTrue/FalseBooleanFalseEnables or disables the double-click prevention filter.
Prevention Time>0ms500The time period when no additional touches will be reported in prevention area.
Prevention Radius>010-1 mm220The radius of the area around the touch defining area where touches are suppressed.
Object Size RestrictionsOnly reports touches with an object size that is within the defined limits

Max Size Enabled

True/False

Boolean

False

Allows a maximum touch object size.

Max Size

Mechanical Data

10-1·mm0

Max limitation of a touch object (if Max Size Enabled =True).

Min Size Enabled

True/False

Boolean

False

Allows a minimum touch object size.

Min Size

Mechanical Data

10-1·mm0

Min limitation of a touch object (if Min Size Enabled =True).

Miscellaneous Settings

Number Of Reported Touches

1-10 touches

Quantity

2

The number of touches that can be reported simultaneously.

Reflective Edge Filter

True/False

Boolean

FalseUseful when there is a risk that there are highly reflective materials right outside the active touch area

...

Time from the down event until the up event is sent. Setting this to 0 completely disables the possibility to do swiping gestures (or drawing). Setting this to e.g 100ms 100 ms gives the end user 100ms 100 ms to move outside of the set Distance (described below) and begin the swipe gesture instead. 

...

This value indicates how long this filter would need to validate the first reported touch. Default value is 400 40 ms. With a lower value the risk increases that a false touch would be reported, and the opposite with a higher value.

...