Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published by Scroll Versions from space ZAMCD and version 3.7

Required Equipment

The following equipment from the evaluation kit is required:

...

Include Page
Required Equipment using Interface board
Required Equipment using

...

Interface board


Additional required equipment:

  • Computer
    • Operating system: Windows 8.1 or Windows 10.
    • Software requirements: .NET Framework 4.5 or higher is required and can be downloaded from Microsoft's official website. Windows 8 and higher has this installed by default.
  • USB cable with a Micro USB type B connector

    Warning

    Make sure that the USB cable transmits both power and data and not only power.

  • (Optional) tape for mounting

Connecting Sensor Module

  1. Connect the FPC cable to the interface board:
    Image Removed
    1. Lift the flip lock on the interface board.
    2. Insert the FPC cable into the end of the connector, with the connector pads facing down, towards interface board. The yellow piece of PCB of the connector on the other side of the cable is facing upwards. Make sure the direction is straight into the connector and the pads have reached the end of the connector.

    3. Make sure the connector pads of the FPC cable are facing downwards, towards interface board. The sensor module risks damage if the FPC cable is connected in wrong direction.

    4. Press down the flip lock.

  2. Connect the FPC cable to the sensor module:
    Image Removed

It is very important to be careful when connecting the sensor to a FPC cable! No excessive force may be applied! No bending is allowed! This may cause the PCB to detach or break. 

...

  1. Place the sensor module so that the module's connector pads are facing downwards (steel surface upwards).
  2. Insert the sensor module into the connector on FPC cable (yellow piece of PCB of the FPC connector still facing upwards).
  3. Make sure the direction of the pads is straight into the connector, and the pads have reached the end of the connector.

...

Connect a USB cable with a Micro USB type B connector to the interface board.
Image Removed

...

Make sure no object is within the touch active area of the sensor module before connecting power to the sensor through USB. The sensor calibrates itself when powered on and an object within the touch active area may interfere with the calibration.

  1. If the sensor module is of the 0° type: place the module on a table with the steel surface facing downwards and with the optical surface facing towards you.
    Image Removed

  2. If the sensor module is of the 90° type: place the module on a table with the steel surface facing upwards, so the optical surface is facing upwards as well. Make sure no object is within the touch active area above the sensor module. 

    Image Removed

    1.  Alternatively, you can mount the sensor module by using tape in order to fasten the steel surface to the edge of a table, with the optical surface facing towards you.
      Image Removed

...

Insert the USB cable into a computer.

Image Removed

Connecting Sensor Module

Include Page
Connecting Sensor Module using Interface board
Connecting Sensor Module using Interface board

...




Install and Open Neonode Workbench

...