Configuration | Range | Measurement | Default | Description |
Range Settings | Sets the scanning range dynamically | |||
Scanning Range | 10-1·mm | Mechanical Data (col. B * 10) | The area (width and height / columns and rows) the TSM will scan for an object with lasers and photodiodes (PD). This value also sets the limit for Max Y below. | |
Touch Active Area Adjustments | Contains settings for modifying the active touch area and the reported touch coordinates | |||
Low Bound X (Min X) | 10-1·mm | 36 | Start position of the (Sub)TAA in x-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. | |
Low Bound Y (Min Y) | 10-1·mm | 0 | Start position of the (Sub)TAA in y-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. | |
High Bound X (Max X) | 10-1·mm | Mechanical Data (col. A * 10) + 36 | End position of the (Sub)TAA in x-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. | |
High Bound Y (Max Y) | 10-1·mm | Mechanical Data (col. B * 10) | End position of the (Sub)TAA in y-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. | |
Reverse X | True/False | Boolean | False | Reverses the x-coordinates of reported touches. |
Reverse Y | True/False | Boolean | False | Reverses the y-coordinates of reported touches. |
Flip XY | True/False | Boolean | False | Swaps the y- with the x-coordinates of the reported touches. |
Offset X | 10-1·mm | 0 | Offsets the projected (Sub)TAA in x-direction, on the display. | |
Offset Y | 10-1·mm | 0 | Offsets the projected (Sub)TAA in y-direction, on the display. | |
HID Display Size | The size of the display reported by the Touch Sensor Module to the host. Only usable when connecting with USB HID | |||
Hid Display Size X | 10-1·mm | Mechanical Data (col. A * 10) | Width of the display. | |
Hid Display Size Y | 10-1·mm | Mechanical Data (col. B * 10) | Height of the display. | |
Object Size Restrictions | Only reports touches with an object size that is within the defined limits | |||
Max Size Enabled | True/False | Boolean | False | Allows a maximum touch object size. |
Max Size | 10-1·mm | 0 | Max limitation of a touch object (if Max Size Enabled =True). | |
Min Size Enabled | True/False | Boolean | False | Allows a minimum touch object size. |
Min Size | 10-1·mm | 0 | Min limitation of a touch object (if Min Size Enabled =True). | |
Click On Touch | Configures the Touch Sensor Module to send an Up (touch event) after Down within a defined threshold to create an instant touch experience | |||
Enabled | True/False | Boolean | False | Enables and disables the Click On Touch Feature |
Time To Up | ms | 100 | Time from the Down event until the Up event is sent. | |
Distance | 10-1·mm | 100 | Distance from the initial location that a touch must stay within for Click On Touch to be enabled for a touch | |
Frequency Settings | Changes the Touch Sensor Modules update frequency | |||
Idle Frequency | Frequency | Hz | 100 | Scanning frequency when the Touch Sensor Module has not registered any touch object. |
Finger Frequency | Frequency | Hz | 33 | Scanning frequency when the Touch Sensor Module has registered and tracking a touch object. |
Floating Protection Settings | Wait for the object to stabilize on the Y-axis, in order to identify the position of the object in a reliable way | |||
Enabled | True/False | Boolean | True | Floating protection enabled |
Floating Protection Time | 10-1·ms | 400 | Time to wait before reporting touch registration | |
Miscellaneous Settings | ||||
Number Of Reported Touches | 1-10 touches | Quantity | 2 | The number of touches that can be reported simultaneously. |
Reflective Edge Filter | True/False | Boolean | False | Useful when there is a risk that there are highly reflective materials right outside the active touch area |
...