Configuration

Range

Measurement

Default

Description

Range Settings


Sets the scanning range dynamically
Scanning Range

Mechanical Data

10-1·mm

Mechanical Data (col. B * 10)

The area (width and height / columns and rows) the TSM will scan for an object with lasers and photodiodes (PD). 

This value also sets the limit for Max Y below.






Touch Active Area Adjustments


Contains settings for modifying the active touch area and the reported touch coordinates

Low Bound X (Min X)

Mechanical Data

10-1·mm

36

Start position of the (Sub)TAA in x-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. 

Low Bound Y (Min Y)

Mechanical Data

10-1·mm

0

Start position of the (Sub)TAA in y-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. 

High Bound X (Max X)

Mechanical Data

10-1·mm

Mechanical Data (col. A * 10) + 36

End position of the (Sub)TAA in x-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. 

High Bound Y (Max Y)

Mechanical Data

10-1·mm

Mechanical Data (col. B * 10)

End position of the (Sub)TAA in y-direction. Min X, Max X, Min Y & Max Y make up the Touch Active Area. 

Reverse X

True/False

Boolean

False

Reverses the x-coordinates of reported touches.

Reverse Y

True/False

Boolean

False

Reverses the y-coordinates of reported touches.

Flip XY

True/False

Boolean

False

Swaps the y- with the x-coordinates of the reported touches.

Offset X

Mechanical Data

10-1·mm

0

Offsets the projected (Sub)TAA in x-direction, on the display.

Offset Y

Mechanical Data

10-1·mm

0

Offsets the projected (Sub)TAA in y-direction, on the display.






HID Display Size


The size of the display reported by the Touch Sensor Module to the host. Only usable when connecting with USB HID

Hid Display Size X

Mechanical Data

10-1·mm

Mechanical Data (col. A * 10)

Width of the display.

Hid Display Size Y

Mechanical Data

10-1·mm

Mechanical Data (col. B * 10)

Height of the display.






Object Size Restrictions


Only reports touches with an object size that is within the defined limits

Max Size Enabled

True/False

Boolean

False

Allows a maximum touch object size.

Max Size

Mechanical Data

10-1·mm0

Max limitation of a touch object (if Max Size Enabled =True).

Min Size Enabled

True/False

Boolean

False

Allows a minimum touch object size.

Min Size

Mechanical Data

10-1·mm0

Min limitation of a touch object (if Min Size Enabled =True).






Click On Touch


Configures the Touch Sensor Module to send an Up (touch event) after Down within a defined threshold to create an instant touch experience
Enabled

True/False

Boolean

FalseEnables and disables the Click On Touch Feature
Time To Up
ms100Time from the Down event until the Up event is sent.
Distance
10-1·mm100Distance from the initial location that a touch must stay within for Click On Touch to be enabled for a touch





Frequency Settings


Changes the Touch Sensor Modules update frequency
Idle FrequencyFrequencyHz100Scanning frequency when the Touch Sensor Module has not registered any touch object.
Finger FrequencyFrequencyHz33Scanning frequency when the Touch Sensor Module has registered and tracking a touch object.





Floating Protection Settings


Wait for the object to stabilize on the Y-axis, in order to identify the position of the object in a reliable way
Enabled

True/False

Boolean

TrueFloating protection enabled
Floating Protection Time
10-1·ms400Time to wait before reporting touch registration





Miscellaneous Settings



Number Of Reported Touches

1-10 touches

Quantity

2

The number of touches that can be reported simultaneously.

Reflective Edge Filter

True/False

Boolean

FalseUseful when there is a risk that there are highly reflective materials right outside the active touch area

...