Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published by Scroll Versions from space ZAMCD and version 3.13

...

Item Specification 
Input methods

Finger, hand or glove.
For details, refer to Touch Performance

Minimum object size (diameter)

5 mm
For details, refer to Touch Performance

Number of touch objects1, 2, or more, depending on application
Touch resolution0.1 mm
Touch activation force0 N (no activation force required)
Touch Active Area

Up to 374.4 x 357.4 mm. For details, refer to .Mechanical Data v3.3

Response time

~50 ms (initial touch, at 33 Hz in idle mode)

10 ms (continuous tracking, at 100 Hz in active mode)

Scanning frequencyConfigurable up to 900 to 900 Hz, depending on product variant. For details, refer to Touch Performance.

Application usage

Contactless touch, touch on surface & object detection

...

The specified values are valid for the used test setup. For more information, refer to Performance Test Methods. The touch accuracy is measured with complete object inside the TAA on surface, using a silicone based cylindrical test rod with a diameter of 16 mm. 

...

The accuracy specification with a Y-range above 208 mm is preliminary and forevaluation purpose only.There are no guarantees concerning the accuracy values for the maximum TAA. Please contact our support team and refer to Firmware Release Notes for further information.  

...

[1] Both active and idle power consumption is specified for default configuration. For details, refer to Power consumption.