Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published by Scroll Versions from space ZAMCD and version 4.1

...

Bit position reserved for

8th and 7th

6th

5th to 1st

Specific bit value



 

 

Binary representation 

XX00 0000

00X0 0000

000X XXXX

Decimal representation 0, 64, 128, 1920 or 320 to 30 (31 is reserved, see the table below)
Hexadecimal representation0x00, 0x40, 0x80, 0xC00x00 or 0x200x00 to 0x1E (0x1F is reserved, see the table below)

Description

Class tagPrimitive/sequenceTag number

...

Step

What to do

Details

Result

The message

1

Add the code for a request, since the message will be sent from the host to the sensor module: 0xEE 0xXX

EE XX

EE XX

2

Add the device address 0x40 0x02 0x02 0x00

See Device Address.

40 02 02 00

EE XX 40 02 02 00

3

Add the bytes for deviceConfiguration

The command deviceConfiguration has the class tag Application, tag number 19 and is a sequence.

Binary: 0111 0011
Hexadecimal: 0x73.

EE XX 40 02 02 00 73

4

Add the bytes for SubTouchActiveArea

SubTouchActiveArea is a context-specific sequence with tag number 2.  

Binary: 1010 0010
Hexadecimal: 0xA2  

EE XX 40 02 02 00 73 XX A2 XX

5

Add the variables inside of SubTouchActiveArea..

All the variables are context-specific and primitive (binary 1000 0000, hexadecimal 0x80). Depending on which variable that is currently being added, add the specific tag number.

Per variable:
Binary: 1000 0000 plus tag number.
Hexadecimal: 0x80 plus tag number.

EE XX 40 02 02 00 73 XX A2 XX 80 XX 01 F4 81 XX 01 F4 82 XX 07 D0 83 XX 07 D0

6

Add the length bytes of the message.

Add the number of bytes for each specific part of the message.

-

EE 18 40 02 02 00 73 12 A2 10 80 02 01 F4 81 02 01 F4 82 02 07 D0 83 02 07 D0



Panel
borderColordarkblue
bgColorlightgrey
titleRead More

Read More on Software Integration

Children Display
pageSoftware Integration


Read More

Children Display
depth1
pageNeonode® Touch Sensor Module User's Guide