Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published by Scroll Versions from space ZAMCD and version 3.2

...

Item Specification 
Input methods

Finger, hand or glove.
For details, refer to Touch Performance

Minimum object size (diameter)

5 mm
For details, refer to Touch Performance

Number of touch objects1, 2, or more, depending on application
Touch resolution0.1 mm
Touch activation force0 N (no activation force required)
Touch Active Area

Up to 345.6 x 327.7 mm. For details, refer to information on product variants in Introduction.

Response time

~50 ms (initial touch, at 33 Hz in idle mode)

10 ms (continuous tracking, at 100 Hz in active mode)

Scanning frequencyConfigurable up to 900 Hz, depending on product variant. For details, refer to Touch Performance.

Application usage

Contactless touch, touch on surface & object detection

Touch accuracy

The specified values are valid for the used test setup. For more information, refer to Performance Test Methods. The touch accuracy is measured with complete object inside the TAA on surface, using a silicone based cylindrical test rod with a diameter of 16 of 16 mm. 

Touch Accuracy

...

within the default Touch Active Area for Sensor Modules

...

90° and 0° Types 

Product Number

Typical Value (mm)

μ ± 2σ (mm)
NNAMC3740PC011.53.5
NNAMC346XPC011.53.5
NNAMC310XPC011.53.5
NNAMC295XPC011.53.5
NNAMC230XPC011.53.5
NNAMC209XPC011.53.5
NNAMC180XPC011.53.5
NNAMC158XPC011.53.5
NNAMC122XPC011.53.5
NNAMC115XPC011.54
NNAMC1011PC011.54

Typical Value: The accuracy on average, within the TAA. 
μ ± 2σ: 95% of reported touch positions deviate less than this value. (2σ standard deviation).
Product number: "X" indicates if indicates if the sensor module is of type 0º ("0") or 90º 90º ("1"). In this case the accuracy specifications in the table are valid for both types.

The accuracy specification (normal range, 0° and 90°) is valid for units produced from 15th January 2020. Please contact our support team for specification regarding earlier produced sensor modules, or general questions about the accuracy specification. 


Touch Accuracy

...

within the maximum Y-axis Touch Active Area for Sensor Modules of the 90° and 0° Types

Product Number

Typical Value (mm)

μ ± 2σ (mm)

NNAMC3740PC01

2.5 

NNAMC346XPC01

2.5

[1]5 [1]

NNAMC310XPC01

2.5

NNAMC295XPC01

2.5 

Typical Value: The accuracy on average, within the TAA. 
μ ± 2σ: 95% of reported touch positions deviate less than this value. (2σ standard deviation).
Product number: "X" indicates if the sensor module is of type 0º ("0") or 90º 90º ("1").
[1] The extended range FW is for evaluation purpose only, thus these values are preliminary and not guaranteed. In this case the accuracy specifications in the table are valid for both types.

The accuracy specification for the maximum Y-axis Touch Active Areas, with a Y-range above 208 mm, The accuracy specification (extended range, 0° and 90°) is preliminary and forevaluation purpose only.There are no guarantees concerning the accuracy values for extended range.   Please contact our support team for more and refer to Firmware Release Notes for further information.  

 


Technical Specification

Item Sensor module Variant Specification 

Module size (LxHxW)

0° Type

L x 3.46 x 14.5 mm 

L depending on product variant.

90° Type

­L x 3.46 x 16.05 mm

L depending on product variant.

Power consumption
I2C interface
Active mode (100 Hz)
NNAMC0720PC01,
NNAMC0721PC0157 mWNNAMC2090PC01,
NNAMC2091PC0180 mWNNAMC3460PC01,
NNAMC3461PC01104 mW

NNAMC3460PC01,
NNAMC3461PC01,

Extended Range

135 mWPower consumption
I2C interface
Idle mode
NNAMCXXXXPC01<130 mW [1]

Power consumption
Idle mode (33 Hz)

NNAMC0720PC01,
NNAMC0721PC0144 mWNNAMC2090PC01,
NNAMC2091PC0145 mWNNAMC3460PC01,
NNAMC3461PC0147 mW

NNAMC3460PC01,
NNAMC3461PC01,

Extended Range

61 mW
NNAMCXXXXPC01<70 mW [1]

[1] Both active and idle power consumption is specified for default configuration. For details, refer to Power consumption.